ME home
 
  SME FaceBook SME Twitter SME LinkedIn RSS Feed

Subscriber or
SME Member Log On

WEB-ONLY CONTENT

Go to SME eNEWS

MINING INDUSTRY EVENTS

Economic Evaluation & Investment Decision Methods  - Short Course
Jul 23, 2018 - Jul 26, 2018
2018 ASISC Paradigms in Mineral Processing Tech  - Conference
Aug 7, 2018 - Aug 9, 2018
Extraction 2018  - Conference
Aug 26, 2018 - Aug 29, 2018
World Congress on Computer Science, Machine learni  - Conference
Aug 30, 2018 - Aug 31, 2018

METAL PRICES


Au
Ag
Pt
Pd
Ni
Cu
Al
Pb

AGGREGATES
AND MINERALS
MARKETPLACE


http://aggregatesmineralsmarketplace.com
The Mining Engineering, SME and NSSGA
Online Buyers Directory Site
The Online Global Mining and Minerals Library Site
March 2018
Volume 70    Issue 3

Refuge alternatives relief valve testing and design with updated test stand

Mining Engineering, 2018, Vol. 70, No. 3, pp. 46-50
Lutz, T.J.; Bissert, P.T.; Homce, G.T.; Yonkey, J.A.

DOI: https://doi.org/10.19150/me.8136

ABSTRACT:

Underground refuge alternatives require an air source to supply breathable air to the occupants. This requires pressure relief valves to prevent unsafe pressures from building up within the refuge alternative. The U.S. Mine Safety and Health Administration (MSHA) mandates that pressure relief valves prevent pressure from exceeding 1.25 kPa (0.18 psi), or as specified by the manufacturer, above mine atmospheric pressure when a fan or compressor is used for the air supply. The U.S. National Institute for Occupational Safety and Health (NIOSH) tested a variety of pressure relief valves using an instrumented test fixture consisting of data acquisition equipment, a centrifugal blower, ductwork and various sensors to determine if the subject pressure relief valves meet the MSHA requirement. Relief pressures and flow characteristics, including opening pressure and flow rate, were measured for five different pressure relief valves under a variety of conditions. The subject pressure relief valves included two off-the-shelf modified check valves, two check valves used in MSHA-approved built-in-place refuge alternatives, and a commercially available valve that was designed for a steel refuge alternative and is currently being used in some built-in-place refuge alternatives. The test results showed relief pressures ranging from 0.20 to 1.53 kPa (0.03 to 0.22 psi) and flow rates up to 19.3 m3/min (683 scfm). As tested, some of the pressure relief valves did not meet the 1.25 kPa (0.18 psi) relief specification.



Please login to access this article.

OR

If you are not an SME member, you can join SME by clicking the button below.