ME home
 
  SME FaceBook SME Twitter SME LinkedIn RSS Feed

Subscriber or
SME Member Log On

WEB-ONLY CONTENT

Go to SME eNEWS

MINING INDUSTRY EVENTS

2018 SME Annual Conference & Expo  - Conference
Feb 25, 2018 - Feb 28, 2018
PDAC 2018 International Convention  - Conference
Mar 4, 2018 - Mar 7, 2018
Aggregates Academy & Expo AGGI 2018  - Conference
Mar 6, 2018 - Mar 8, 2018
Society of Mining Professors Regional Conference  - Conference
Mar 12, 2018 - Mar 13, 2018

METAL PRICES


Au
Ag
Pt
Pd
Ni
Cu
Al
Pb

AGGREGATES
AND MINERALS
MARKETPLACE


http://aggregatesmineralsmarketplace.com
The Mining Engineering, SME and NSSGA
Online Buyers Directory Site
The Online Global Mining and Minerals Library Site
October 2015
Volume 67    Issue 10

Fenceline PM4 crystalline silica concentrations near sand mining and processing facilities in Wisconsin

Mining Engineering, 2015, Vol. 67, No. 10, pp. 53-59
Richards, J.; Brozell, T.


ABSTRACT:

Communities near sand mines and processing facilities in Wisconsin have raised concerns regarding possible exposure to ambient respirable (PM4) crystalline silica. Fenceline PM4 (particulate matter captured with a 50-percent cut size of 4 micrometers aerodynamic diameter) crystalline silica concentration data were compiled at Fairmount Santrol Inc., Mathy Construction Inc. and U.S. Silica facilities. The long-term average PM4 crystalline silica concentrations ranged from 0.05 to 0.45 micrograms/m3 when sample values below the limit of quantification were treated as zeros. All of the long-term average concentrations were less than 20 percent of the Minnesota Department of Health’s and California Office of Environmental Health Hazard Assessment’s PM4 crystalline silica chronic reference exposure level of 3.0 micrograms/m3. The measured concentrations were consistently within the local background concentration range.

  Air Control Techniques P.C. compiled the sampling data using Thermo Fisher Scientific Inc. Partisol 2000i PM2.5 samplers meeting the requirements of 40 CFR Part 50, Appendix L. These samplers were adapted to capture particulate matter with a 50-percent cut size of 4 micrometers. The use of polyvinyl chloride filters allowed for crystalline silica X-ray diffraction analysis by NIOSH Method 7500. The combined use of adjusted PM2.5 filter-based samplers with Method 7500 crystalline silica analyses provided for a highly sensitive limit of quantification of 0.31 micrograms/m3 of PM4 crystalline silica. 


Please login to access this article.

OR

If you are not an SME member, you can join SME by clicking the button below.